    The Development of Appropriate Brine Electrolysers for Disinfection of Rural water supplies

    Thumbnail
    View/Open
    Thesis (72.94Mb)
    Date
    2005
    Author
    Siguba, Maxhobandile
    Metadata
    Show full item record
    Abstract
    A comparative study of electrolysers using different anodic materials for the electrolysis of brine (sodium chloride) for the production of sodium hypochlorite as a source of A comparative study of electrolysers using different anodic materials for the electrolysis of brine (sodium chloride) for the production of sodium hypochlorite as a source of available chlorine for disinfection of rural water supplies has been undertaken. The electrolyser design used was tubular in form, having two chambers i.e. anode inside and cathode outside, separated by a tubular inorganic ceramic membrane. The anode was made of titanium rod coated with a thin layer of platinum and a further coat of metal oxide. The cathode was made of stainless steel wire. available chlorine for disinfection of rural water supplies has been undertaken. The electrolyser design used was tubular in form, having two chambers i.e. anode inside and cathode outside, separated by a tubular inorganic ceramic membrane. The anode was made of titanium rod coated with a thin layer of platinum and a further coat of metal oxide. The cathode was made of stainless steel wire. An assessment of these electrolysers was undertaken by studying the effects of some variable parameters i.e. current, voltage and sodium chloride concentration. The flow rate was kept unchanged at 50ml/h anolyte and 140ml/h catholyte since it was found to be optimum flow rate for chlorine generation. Figures of merit of the electrolysers were calculated on the basis of three sets of measurements. Analytical methods used for the determination of sodium hypochlorite concentration were iodometric and N, N-Diethyl-p- Phenylenediamine (DPD) titration methods. The DPD titration method was used to determine the chlorine concentration of less than 1mg/L, while the iodometric titration method was used to determine chlorine concentration of ImgIL and above. Sodium chlorate present in the hypochlorite solution was also determined using a spectrophotometric method. The cobalt oxide electrolyser has been shown to be superior as compared to the ruthenium dioxide and manganese dioxide electrolysers in terms of hypochlorite generation. Sodium chlorate was present but at concentration levels not hazardous for use in dosing water for drinking purposes. Analysis of hydroxyl radicals was undertaken since there were claims that these are produced during brine electrolysis. Hydroxyl radical analysis was not successful, since sodium hypochlorite and hypochlorous acid interfere using the analytical method described in this study.
    URI
    http://hdl.handle.net/11394/8874
    Collections
    • Magister Scientiae - MSc (Chemistry)

    DSpace 6.3 | Ubuntu | Copyright © University of the Western Cape
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of RepositoryCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    Login

    Statistics

    View Usage Statistics

    DSpace 6.3 | Ubuntu | Copyright © University of the Western Cape
    Contact Us | Send Feedback
    Theme by 
    @mire NV